Deionised Water 25l – Identification of Product
Chemical Code: CHE-D1
Chemical Name: Water De-ionised
Chemical Grade:
Chemical Formula: H₂O
Chemical Weight: 18,02 g/mol
CAS No: 7732-18-5
Chemical Synonyms: De-ionised Water
Deionised Water 25l – Hazards Identification
REACH No: No Data Available
Signal Word:
Supplemental Hazard Information: Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
Additional Hazard Information:
Deionised Water 25l – Composition of Chemical
Chemical Formula: H₂O
EC No 1272/2008: No Data Available
Deionised Water 25l – First Aid Measures
General Advice: No Data Available
If: Inhaled: If not breathing give artificial respiration.
If: Skin Contact: No Data Available
If: Eye Contac: No Data Available
If: Swallowed: No Data Available
Important Symptoms: The most important known symptoms and effects are described in the labeling section.
Immediate Medical Attention: No Data Available
Firefighting Measures
Extinguishing Media: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Hazards Arising: No Data Available
Advice for Firefighters: No Data Available
Info for Firefighting: The product itself does not burn.
Deionised Water – Accidental Release Measures
Personal Precautions: No Data Available
Enviromental Precautions: No Data Available
Method for Containment: Wipe up with absorbent material (e.g. cloth, fleece).
Handling and Storage
Personal Precautions: No Data Available
Enviromental Precautions: No special storage conditions required.
Exposure Controls | Personal Protection
Derived No Effect Level (DNEL)
Workers | Application Area | Exposure Routes | Health Effect | Value
No Data Available
Consumers | Application Area | Exposure Routes | Health Effect | Value
No Data Available
Predicted No Effect Concentration (PNEC)
No Data Available
Engineering Controls: Handle in accordance with good industrial hygiene and safety practice.
Eye/Face Protection: No Data Available
Skin Protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching gloves outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Immersion protection
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: > 480 min
Material tested: Dermatril® (Size M)
Splash protection Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: > 30 min
Material tested: Dermatril® (Size M)
Data source: KCL GmbH, D-36124 Test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an Industrial Hygienist familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Body Protection: No Data Available
Respiratory Protection: No special protective equipment required.
Physical and Chemical Properties
Appearance: Colourless Liquid
Odour: No Data Available
Odour Threshold: No Data Available
pH: 6,0 – 8,0 at 25 °C
Melting Point: 0,0 °C
Boiling Point: 100 °C – lit.
Flash Point: Not Applicable
Evaporation: No Data Available
Flammability: No Data Available
Upper/Lower Flammability or Explosive Limits: No Data Available
Vapour pressure: No Data Available
Vapour density: No Data Available
Relative density: 1,000 g/cm3 at 3,98 °C
Water solubility: Completely Miscible
Partition Coefficien: No Data Available
Auto-ignition Temperature: No Data Available
Decomposition Temperature: No Data Available
Viscosity: No Data Available
Explosive properties: No Data Available
Oxidizing properties: No Data Available
Other Safety Info: No Data Available
Stability and Reactivity
Reactivity: No Data Available
Chemical Stability: No Data Available
Possibility of hazardous reactions: No Data Available
Conditions to Avoid: No Data Available
Incompatible Materials: No Data Available
Hazardous Decomposition Products: No Data Available
Toxicological Information
Acute Toxicity: No Data Available
Skin Corrosion/Irritation: No Data Available
Serious Eye damage | Eye Irritation: No Data Available
Cell Mutagenicity: No Data Available
Carcinogenicity: IARC: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity: No Data Available
Specific Target Organ Toxicity – Single Exposure: No Data Available
Specific Target Organ Toxicity – Repeated Exposure: No Data Available
Aspiration Hazard: No Data Available
Ecological Information
Ecological Toxicity: No Data Available
Ecological Persistence and degradability: No Data Available
Bioaccumulative Potential: No Data Available
Mobility in Soil: No Data Available
Results of PBT and vPvB Assessment: PBT/vPvB assessment not available as chemical safety assessment not required/not conducted.
Other Adverse Effect: No Data Available
Disposal Considerations
Waste Treatment Methods: Taking into account local regulations the product may be disposed of as waste water after neutralization.
Transport Information
UN Number: ADR/RID: –
IMDG: –
IATA: –
UN Shipping Hazard: ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
Transport Hazard Class: ADR/RID: –
IMDG: –
IATA: –
Packaging Group: ADR/RID: –
IMDG: –
IATA: –
Enviromental Hazards: ADR/RID: no
IMDG Marine pollutant: no
IATA: no
Special Precautions: No Data Available
Regulatory Information
Safety, Health and environmental regulations: This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
Chemical Safety Assessment: For this product a chemical safety assessment was not carried out.
Additional Info: RTECS: ZC0110000
Disclaimer
The information stated above is considered to be correct, but does not claim to be inclusive and shall only be used as a guideline. The information provided by this document is confirmed by our continuous updating of knowledge and adheres to the products appropriate safety precautions. It does not represent any guarantee of the product’s
properties. RLS Chemicals and its Associates shall not be held accountable for any damage’s consequent of handling the above product.