Potassium Iodide AR – 500g

R1,585.85 Incl VAT

CAS Number:584-08-7

Synonyms

  • Carbonate of Potash
  • Dipotassium Carbonate
  • Sub-Carbonate of Potash

Availability: 17 in stock (can be backordered)

Add to Wishlist
Add to Wishlist
SKU: CHE-P14 Category:

Potassium Iodide AR – Identification of Product
Chemical Code: CHE-P14
Chemical Name: Potassium Iodide
Chemical Grade:
Chemical Formula: IK
Chemical Weight: 166,00 g/mol
CAS No: 7681-11-0
Chemical Synonyms:

Potassium Iodide AR – Hazards Identification
REACH No: No Data Available
Signal Word: Warning
Supplemental Hazard Information:
Additional Hazard Information: No Data Available

Potassium Iodide AR – Hazards statements
H302 – Harmful if swallowed.
H315 – Causes skin irritation.
H319 – Causes serious eye irritation.

Potassium Iodide AR – Precautionary statements
P305 + P351 + P338 – IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Potassium Iodide AR – Composition of Chemical
Chemical Formula: IK
EC No 1272/2008: No Data Available

First Aid Measures
General Advice: Consult a physician. Show this safety data sheet to the doctor in attendance.
If: Inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
If: Skin Contact: Wash off with soap and plenty of water. Consult a physician.
If: Eye Contac: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If: Swallowed: Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Important Symptoms: The most important known symptoms and effects are described in the labeling section.
Immediate Medical Attention: No Data Available

Firefighting Measures
Extinguishing Media: Dry powder
Hazards Arising: Sulphur oxides, Potassium oxides.
Advice for Firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
Info for Firefighting: No Data Available

Accidental Release Measures
Personal Precautions: Wear respiratory protection. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
Enviromental Precautions: Do not let product enter drains.
Method for Containment: Pick up and arrange disposal without creating dust. Sweep up and shovel. Do not flush with water. Keep in suitable, closed containers for disposal.

Handling and Storage
Personal Precautions: Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.
Enviromental Precautions: Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Never allow product to get in contact with water during storage. Do not store near acids.
Exposure Controls | Personal Protection
Derived No Effect Level (DNEL)
Workers | Application Area | Exposure Routes | Health Effect | Value
No Data Available
Consumers | Application Area | Exposure Routes | Health Effect | Value
No Data Available
Predicted No Effect Concentration (PNEC)
No Data Available
Engineering Controls: Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Eye/Face Protection: Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin Protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove’s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Full contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: 480 min
Material tested: Dermatril® (KCL 740 / Size M)
Splash contact
Material: Nitrile rubber
Minimum layer thickness: 0,11 mm
Break through time: 480 min
Material tested: Dermatril® (KCL 740 / Size M)
data source: KCL GmbH, D-36124 , test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Body Protection: Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory Protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Physical and Chemical Properties
Appearance: Colourless or White crystals or granules or powder
Odour: No Data Available
Odour Threshold: No Data Available
pH: 6,0 – 9 at 166 g/l at 25 °C
Melting Point: Melting Point/Range: 681 °C
Boiling Point: 1.330 °C
Flash Point: No Data Available
Evaporation: No Data Available
Flammability: No Data Available
Upper/Lower Flammability or Explosive Limits: No Data Available
Vapour pressure: 1 hPa at 745 °C
Vapour density: No Data Available
Relative density: 3,130 g/cm3
Water solubility: No Data Available
Partition Coefficien: No Data Available
Auto-ignition Temperature: No Data Available
Decomposition Temperature: No Data Available
Viscosity: No Data Available
Explosive properties: No Data Available
Oxidizing properties: No Data Available
Other Safety Info: Bulk density 1.700 kg/m3

Stability and Reactivity
Reactivity: No Data Available
Chemical Stability: May decompose on exposure to air and moisture.
Stable under recommended storage conditions.
Possibility of hazardous reactions: No Data Available
Conditions to Avoid: Tin/tin oxides.
Incompatible Materials: Strong reducing agents, Nickel, Strong acids, and its alloys, Steel (all types and surface treatments), Aluminum, Alkali metals, Brass, Magnesium, Zinc, cadmium, Copper.
Hazardous Decomposition Products: Other decomposition products – No Data Available

Toxicological Information
Acute Toxicity: LD50 Oral – mouse – 1.000 mg/kg
Skin Corrosion/Irritation: Skin – rabbit
Result: Irritating to skin.
Serious Eye damage | Eye Irritation: Eyes – rabbit
Result: Irritating to eyes. – 24 h (Draize Test)
Cell Mutagenicity: No Data Available
Carcinogenicity: IARC: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity: Exposure to excessive amounts of iodine during pregnancy is capable of producing fetal hypothyroidism.
Iodine-containing drugs have been associated with fetal goiter.
Specific Target Organ Toxicity – Single Exposure: No Data Available
Specific Target Organ Toxicity – Repeated Exposure: No Data Available
Aspiration Hazard: No Data Available

Ecological Information
Ecological Toxicity: Toxicity to fish LC50 – Oncorhynchus mykiss (rainbow trout) – 2.190 mg/l – 96 h
Toxicity to daphnia and other aquatic invertebrates – EC50 – Daphnia – 2,7 mg/l – 24 h
Ecological Persistence and degradability: No Data Available
Bioaccumulative Potential: No Data Available
Mobility in Soil: No Data Available
Results of PBT and vPvB Assessment: PBT/vPvB assessment not available as chemical safety assessment not required/not conducted.
Other Adverse Effect: No Data Available

Disposal Considerations
Waste Treatment Methods: Product
Offer surplus and non-recyclable solutions to a licensed disposal company.

Contaminated packaging
Dispose of as unused product

Transport Information
UN Number: ADR/RID: –
IMDG: –
IATA: –
UN Shipping Hazard: ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
Transport Hazard Class: ADR/RID: –
IMDG: –
IATA: –
Packaging Group: ADR/RID: –
IMDG: –
IATA: –
Enviromental Hazards: ADR/RID: no
IMDG Marine pollutant: no
IATA: no
Special Precautions: No Data Available

Regulatory Information
Safety, Health and environmental regulations: This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
Chemical Safety Assessment: For this product a chemical safety assessment was not carried out.
Additional Info: RTECS: TT2975000
Prolonged exposure to iodides may produce iodism in sensitive individuals. Symptoms of exposure include: skin rash, running nose, headache and irritation of the mucous membrane. For severe cases the skin may show pimples, boils, hives, blisters and black and blue spots. Iodides are readily diffused across the placenta. Neonatal deaths from respiratory distress secondary to goiter have been reported. Iodides have been known to cause drug-induced fevers, which are usually of short duration. Liver – Irregularities –
Based on Human Evidence.

VIEW MSDS BUTTON
VIEW sPECSHEET BUTTON

DisclaimerThe information stated above is considered to be correct, but does not claim to be inclusive and shall only be used as a guideline. The information provided by this document is confirmed by our continuous updating of knowledge and adheres to the products appropriate safety precautions. It does not represent any guarantee of the product’s
properties. RLS Chemicals and its Associates shall not be held accountable for any damage’s consequent of handling the above product.

Shopping Cart
Scroll to Top
× How can I help you?