Thymol Blue Indicator

R62.70R100.25 Incl VAT

Reflecta Laboratory Supplies provide quality chemical solutions and reagents manufactured inhouse. Our RLS Chemical solution complies with NIST standards

Add to Wishlist
Add to Wishlist
SKU: N/A Category:

Thymol Blue Indicator – Identification of Product
Chemical Code: RLS-SOL-T01 to T02
Chemical Name: Thymol Blue indicator solution
Chemical Grade:
Chemical Formula: No Data Available
Chemical Weight:
CAS No:
Chemical Synonyms: Thymolsulphonephthalein indicator solution

Thymol Blue Indicator – Hazards Identification
REACH No:
Signal Word:
Supplemental Hazard Information:
Additional Hazard Information: Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.

Thymol Blue Indicator – Hazards statements
No Data Available

Thymol Blue Indicator – Precautionary statements
No Data Available

Thymol Blue Indicator – Composition of Chemical

Chemical Formula: No Data Available
EC No 1272/2008:

Thymol Blue Indicator – First Aid Measures
General Advice: Obtain medical advice if feeling unwell
If: Inhaled: Move person to fresh air.
If: Skin Contact: Take off immediately all contaminated clothing. Rinse skin with water/shower.
If: Eye Contac: Rinse out with plenty of water.
If: Swallowed: Make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Important Symptoms: We have no description of any toxic symptoms.
Immediate Medical Attention: No Data Available

Thymol Blue Indicator – Firefighting Measures
Extinguishing Media: Water, Foam, Carbon Dioxide, Dry powder.
Hazards Arising: Combustible.
Development of hazardous combustion gases or vapours possible in the event of fire.
Fire may cause evolution of Sulphur Oxides.
Advice for Firefighters: Wear self-contained breathing apparatus.
Info for Firefighting: Suppress (knock down) gases/vapours/mists with a water spray jet.
Prevent fire extinguishing water from contaminating surface water or the ground water system.

Accidental Release Measures
Personal Precautions: Avoid inhalation of dusts.
Evacuate the danger area.
Observe emergency procedures.
Consult an expert.
Environmental Precautions: Do not let product enter drains.
Method for Containment: Cover drains.
Collect, bind, and pump off spills.
Observe possible material restrictions.
Take up dry.
Dispose of properly.
Clean up affected area.
Avoid generation of dusts.

Handling and Storage
Personal Precautions: Change contaminated clothing.
Wash hands after working with substance.
Environmental Precautions: Keep container tightly closed.
Store in a dry place.
Exposure Controls | Personal Protection
Derived No Effect Level (DNEL)
Workers | Application Area | Exposure Routes | Health Effect | Value
No Data Available
Consumers | Application Area | Exposure Routes | Health Effect | Value
No Data Available
Predicted No Effect Concentration (PNEC)
No Data Available
Engineering Controls: Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.
Eye/Face Protection: Wear safety glasses.
Skin Protection: Wear protective gloves. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. For example:
Full contact –
Glove material: Nitrile rubber. Glove thickness: 0.11 mm.
Break through time: > 480 min.
Splash contact –
Glove material: Nitrile rubber. Glove thickness: 0.11 mm.
Break through time: > 480 min.
The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types.
Body Protection: Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled.
Respiratory Protection: Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator with multi-purpose combination, type OV/AG (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Physical and Chemical

Properties Appearance: Liquid
Odour: No Data Available
Odour Threshold: No Data Available
pH: No Data Available
Melting Point: No Data Available
Boiling Point: No Data Available
Flash Point: No Data Available
Evaporation: No Data Available
Flammability: No Data Available
Upper/Lower Flammability or Explosive Limits: No Data Available
Vapour pressure: No Data Available
Vapour density: No Data Available
Relative density: No Data Available
Water solubility: Miscible
Partition Coefficien: No Data Available
Auto-ignition Temperature: No Data Available
Decomposition Temperature: No Data Available
Viscosity: No Data Available
Explosive properties: No Data Available
Oxidizing properties: No Data Available
Other Safety Info: No Data Available

Stability and Reactivity
Reactivity: No Data Available
Chemical Stability: The product is chemically stable under standard ambient conditions.
Possibility of hazardous reactions: Violent reactions possible with strong oxidizing agents.
Conditions to Avoid: No Data Available
Incompatible Materials: No Data Available
Hazardous Decomposition Products: No Data Available

Toxicological Information

Acute Toxicity: No Data Available
Skin Corrosion/Irritation: No Data Available
Serious Eye damage | Eye Irritation: No Data Available
Cell Mutagenicity: No Data Available
Carcinogenicity: No Data Available
Reproductive toxicity: No Data Available
Specific Target Organ Toxicity – Single Exposure: No Data Available
Specific Target Organ Toxicity – Repeated Exposure: No Data Available
Aspiration Hazard: No Data Available

Ecological Information
Ecological Toxicity: No Data Available
Ecological Persistence and degradability: No Data Available
Bio-accumulative Potential: No Data Available
Mobility in Soil: No Data Available
Results of PBT and vPvB Assessment: No Data Available
Other Adverse Effect: Discharge into the environment must be avoided.

Disposal Considerations
Waste Treatment Methods: Waste material must be disposed of in accordance with the national and local regulations. Leave
chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.

Transport Information
UN Number: ADR/RID: —
IATA: —
IMDG: —
UN Shipping Hazard: ADR/RID: —
IATA: —
IMDG: —
Transport Hazard Class: ADR/RID: —
IATA: —
IMDG: —
Packaging Group: ADR/RID: —
IATA: –IMDG: —
Environmental Hazards: ADR/RID: —
IATA: —
IMDG: —
Special Precautions: No Data Available

Regulatory Information
Safety, Health and environmental regulations: This material safety data sheet is in accordance with Regulation (EC) No. 1907/2006.
Chemical Safety Assessment: For this product a chemical safety assessment was not carried out.
Additional Info: Hazardous properties cannot be excluded but are unlikely when the product is handled appropriately.
Handle in accordance with good industrial hygiene and safety practice.


Disclaimer
The information stated above is considered to be correct, but does not claim to be inclusive and shall only be used as a guideline. The information provided by this document is confirmed by our continuous updating of knowledge and adheres to the products appropriate safety precautions. It does not represent any guarantee of the product’s
properties. RLS Chemicals and its Associates shall not be held accountable for any damage’s consequent of handling the above product

Volume

500ml, 1000ml

Shopping Cart
Scroll to Top
× How can I help you?